Avanti JXN-30 Series

Covering all of the applications of a floor-standing centrifuge, the Avanti® JXN-30 features rotor speed of 30,000 RPM and RCF greater than 100,000 x g. Master daily lab challenges with the advanced levels of networking, reliable performance, and improved BioSafety* found in the Avanti JXN-30.

The additional power of the MobileFuge app gives additional flexibility, including the ability to:

  • Access and monitor data remotely
  • Receive system notifications via email 
  • Manage permissions
  • Address error handling and more via networks or mobile devices

Avanti JXN-30 High Performance Centrifuge Features

Easy to use software

  • Simultaneous display of set and actual run conditions
  • Rotor selection by name (not code)
  • 11 acceleration/12 deceleration rates
  • Delay start
  • Run times to 99:59, Hold, and ω2t integrator for applications requiring precise reproducibility

Powerful data management

  • Up to 1,000 user-defined programs
  • Storage for numerous protocols
  • Password protection for up to 50 unique user profiles
  • Networking capability for multiple instruments
  • Data logging and real-time run graphing

15" LED Touchscreen Monitor

  • Built to withstand 10 million touches
  • Backlight life of 50,000 hours
  • LED backlight for 20% power saving and environmental protection

Triple Redundant Safety Systems

  • Windage, inertia, and rotor ID checks via magnets offer triple redundant safety
  • Friction Reduction System (FRS) for quicker, quieter, and cooler runs
  • High-torque, Switched Reluctance (SR) drive cycle for shorter cycle times

Explore Avanti JXN-30 Models

Product Specifications

BioSafe Yes
Acceleration 11 acceleration profiles
Deceleration 12 profiles
Timed Run 1 min to 99 hrs, 59 mins
Max Capacity Volume Range 1 - 4 L
Temperature Control ± 2 °C of set temperature after equilibration
Temperature Range(s) -20° to +40° C
Item Specifications Referenced B37913

Content and Resources

Filter by:
Resource Type
Centrifugation is a Complete Workflow Solution for Protein Purification and Protein Aggregation Quantification Author: Julia P Luciano-Chadee | Beckman Coulter Life Sciences, Inc., Indianapolis, IN 46268 | Published 2017
Friction Reduction System Author: Chad Schwartz, Ph. D., Application Scientist | Beckman Coulter Life Sciences, Indianapolis, IN USA | Published 2014
Product Catalog: High Speed Centrifuges This centrifuge product selection guide is designed to help you determine the most efficient centrifuge tools for your laboratory.
Density Gradient Separation of Gold Nanorods Gold Nanorods (AuNR) hold great promise for biomedical imaging
Avanti JXN Series - Complete Solution for Protein Purification Workflow Purified proteins are required for many proteomics applications such as X-ray crystallography, NMR, mass spec, and in vitro biochemical assays

Technical Documents

Didn't find what you are looking for? For more results click here.